This file is fairly incomplete. Help is welcome.
|
||||
|
||||
Tiers
|
||||
-----
|
||||
The tier is a string, currently `"LV"`, `"MV"` and `"HV"` are supported.
|
||||
|
||||
Network
|
||||
-------
|
||||
The network is the cable with the connected machine nodes. Currently the
|
||||
switching station handles the network activity.
|
||||
|
||||
Helper functions
|
||||
----------------
|
||||
* `technic.pretty_num(num)`
|
||||
* Converts the number `num` to a human-readable string.
|
||||
* Use this function when showing players power values.
|
||||
* `technic.swap_node(pos, nodename)`
|
||||
* Same as `mintest.swap_node` but it only changes the nodename.
|
||||
* It uses `minetest.get_node` before swapping to ensure the new nodename
|
||||
is not the same as the current one.
|
||||
* `technic.get_or_load_node(pos)`
|
||||
* If the mapblock is loaded, it returns the node at pos,
|
||||
else it loads the chunk and returns `nil`.
|
||||
* `technic.set_RE_wear(itemstack, item_load, max_charge)`
|
||||
* If the `wear_represents` field in the item's nodedef is
|
||||
`"technic_RE_charge"`, this function does nothing.
|
||||
* `technic.refill_RE_charge(itemstack)`
|
||||
* This function fully recharges an RE chargeable item.
|
||||
* If `technic.power_tools[itemstack:get_name()]` is `nil` (or `false`), this
|
||||
function does nothing, else that value is the maximum charge.
|
||||
* The itemstack metadata is changed to contain the charge.
|
||||
* `technic.is_tier_cable(nodename, tier)`
|
||||
* Tells whether the node `nodename` is the cable of the tier `tier`.
|
||||
* `technic.get_cable_tier(nodename)`
|
||||
* Returns the tier of the cable `nodename` or `nil`.
|
||||
* `technic.trace_node_ray(pos, dir, range)`
|
||||
* Returns an iteration function (usable in the for loop) to iterate over the
|
||||
node positions along the specified ray.
|
||||
* The returned positions will not include the starting position `pos`.
|
||||
* `technic.trace_node_ray_fat(pos, dir, range)`
|
||||
* Like `technic.trace_node_ray` but includes extra positions near the ray.
|
||||
* The node ray functions are used for mining lasers.
|
||||
* `technic.config:get(name)`
|
||||
* Some configuration function
|
||||
* `technic.tube_inject_item(pos, start_pos, velocity, item)`
|
||||
* Same as `pipeworks.tube_inject_item`
|
||||
|
||||
Registration functions
|
||||
----------------------
|
||||
* `technic.register_power_tool(itemname, max_charge)`
|
||||
* Same as `technic.power_tools[itemname] = max_charge`
|
||||
* This function makes the craftitem `itemname` chargeable.
|
||||
* `technic.register_machine(tier, nodename, machine_type)`
|
||||
* Same as `technic.machines[tier][nodename] = machine_type`
|
||||
* Currently this is requisite to make technic recognize your node.
|
||||
* See also `Machine types`
|
||||
* `technic.register_tier(tier)`
|
||||
* Same as `technic.machines[tier] = {}`
|
||||
* See also `tiers`
|
||||
|
||||
### Specific machines
|
||||
* `technic.register_solar_array(data)`
|
||||
* data is a table
|
||||
|
||||
Used itemdef fields
|
||||
-------------------
|
||||
* groups:
|
||||
* `technic_<ltier> = 1` ltier is a tier in small letters; this group makes
|
||||
the node connect to the cable(s) of the right tier.
|
||||
* `technic_machine = 1` Currently used for
|
||||
* `connect_sides`
|
||||
* In addition to the default use (see lua_api.txt), this tells where the
|
||||
machine can be connected.
|
||||
#
|
||||
#
|
||||
* `technic_run(pos, node)`
|
||||
* This function is currently used to update the node.
|
||||
Modders have to manually change the information about supply etc. in the
|
||||
node metadata.
|
||||
|
||||
Machine types
|
||||
-------------
|
||||
There are currently following types:
|
||||
* `technic.receiver = "RE"` e.g. grinder
|
||||
* `technic.producer = "PR"` e.g. solar panel
|
||||
* `technic.producer_receiver = "PR_RE"` supply converter
|
||||
* `technic.battery = "BA"` e.g. LV batbox
|
||||
|
||||
Switching Station
|
||||
-----------------
|
||||
The switching station is the center of all power distribution on an electric
|
||||
network.
|
||||
|
||||
The station collects power from sources (PR), distributes it to sinks (RE),
|
||||
and uses the excess/shortfall to charge and discharge batteries (BA).
|
||||
|
||||
For now, all supply and demand values are expressed in kW.
|
||||
|
||||
It works like this:
|
||||
All PR,BA,RE nodes are indexed and tagged with the switching station.
|
||||
The tagging is a workaround to allow more stations to be built without allowing
|
||||
a cheat with duplicating power.
|
||||
All the RE nodes are queried for their current EU demand. Those which are off
|
||||
would require no or a small standby EU demand, while those which are on would
|
||||
require more.
|
||||
If the total demand is less than the available power they are all updated with
|
||||
the demand number.
|
||||
If any surplus exists from the PR nodes the batteries will be charged evenly
|
||||
with this.
|
||||
If the total demand requires draw on the batteries they will be discharged
|
||||
evenly.
|
||||
|
||||
If the total demand is more than the available power all RE nodes will be shut
|
||||
down. We have a brown-out situation.
|
||||
|
||||
Hence for now all the power distribution logic resides in this single node.
|
||||
|
||||
### Node meta usage
|
||||
Nodes connected to the network will have one or more of these parameters as meta
|
||||
data:
|
||||
* `<LV|MV|HV>_EU_supply` : Exists for PR and BA node types.
|
||||
This is the EU value supplied by the node. Output
|
||||
* `<LV|MV|HV>_EU_demand` : Exists for RE and BA node types.
|
||||
This is the EU value the node requires to run. Output
|
||||
* `<LV|MV|HV>_EU_input` : Exists for RE and BA node types.
|
||||
This is the actual EU value the network can give the node. Input
|
||||
|
||||
The reason the LV|MV|HV type is prepended to meta data is because some machine
|
||||
could require several supplies to work.
|
||||
This way the supplies are separated per network.
|
@ -1,35 +1,4 @@
|
||||
-- SWITCHING STATION
|
||||
-- The switching station is the center of all power distribution on an electric network.
|
||||
--
|
||||
-- The station collects power from sources (PR), distributes it to sinks (RE),
|
||||
-- and uses the excess/shortfall to charge and discharge batteries (BA).
|
||||
--
|
||||
-- For now, all supply and demand values are expressed in kW.
|
||||
--
|
||||
-- It works like this:
|
||||
-- All PR,BA,RE nodes are indexed and tagged with the switching station.
|
||||
-- The tagging is to allow more stations to be built without allowing a cheat
|
||||
-- with duplicating power.
|
||||
-- All the RE nodes are queried for their current EU demand. Those which are off
|
||||
-- would require no or a small standby EU demand, while those which are on would
|
||||
-- require more.
|
||||
-- If the total demand is less than the available power they are all updated with the
|
||||
-- demand number.
|
||||
-- If any surplus exists from the PR nodes the batteries will be charged evenly with this.
|
||||
-- If the total demand requires draw on the batteries they will be discharged evenly.
|
||||
--
|
||||
-- If the total demand is more than the available power all RE nodes will be shut down.
|
||||
-- We have a brown-out situation.
|
||||
--
|
||||
-- Hence all the power distribution logic resides in this single node.
|
||||
--
|
||||
-- Nodes connected to the network will have one or more of these parameters as meta data:
|
||||
-- <LV|MV|HV>_EU_supply : Exists for PR and BA node types. This is the EU value supplied by the node. Output
|
||||
-- <LV|MV|HV>_EU_demand : Exists for RE and BA node types. This is the EU value the node requires to run. Output
|
||||
-- <LV|MV|HV>_EU_input : Exists for RE and BA node types. This is the actual EU value the network can give the node. Input
|
||||
--
|
||||
-- The reason the LV|MV|HV type is prepended toe meta data is because some machine could require several supplies to work.
|
||||
-- This way the supplies are separated per network.
|
||||
-- See also technic/doc/api.md
|
||||
|
||||
technic.networks = {}
|
||||
technic.cables = {}
|
||||
|