Send changesignals for placed receptors when not powered, make on_placenode code more readable
with comments. Also fixes a bug of lua- / microcontrollers not being updated when pushed by a piston. This could cause some bugs, even though I haven't found any while testing as it is a very core part of mesecons.
This commit is contained in:
parent
a9427d267b
commit
1852e967a9
@ -39,7 +39,6 @@
|
||||
-- }
|
||||
--}
|
||||
|
||||
|
||||
-- PUBLIC VARIABLES
|
||||
mesecon={} -- contains all functions and all global variables
|
||||
mesecon.queue={} -- contains the ActionQueue
|
||||
|
@ -1,19 +1,31 @@
|
||||
mesecon.on_placenode = function (pos, node)
|
||||
-- Receptors: Send on signal when active
|
||||
if mesecon:is_receptor_on(node.name) then
|
||||
mesecon:receptor_on(pos, mesecon:receptor_get_rules(node))
|
||||
elseif mesecon:is_powered(pos) then
|
||||
if mesecon:is_conductor(node.name) then
|
||||
-- receptor_on if itself is powered already
|
||||
end
|
||||
|
||||
-- Conductors: Send turnon signal when powered or replace by respective offstate conductor
|
||||
-- if placed conductor is an onstate one
|
||||
if mesecon:is_conductor(node.name) then
|
||||
if mesecon:is_powered(pos) then
|
||||
-- also call receptor_on if itself is powered already, so that neighboring
|
||||
-- conductors will be activated (when pushing an on-conductor with a piston)
|
||||
mesecon:turnon (pos)
|
||||
mesecon:receptor_on (pos, mesecon:conductor_get_rules(node))
|
||||
else
|
||||
elseif mesecon:is_conductor_off(node.name) then
|
||||
minetest.swap_node(pos, {name = mesecon:get_conductor_off(node)})
|
||||
end
|
||||
end
|
||||
|
||||
-- Effectors: Send changesignal and activate or deactivate
|
||||
if mesecon:is_effector(node.name) then
|
||||
if mesecon:is_powered(pos) then
|
||||
mesecon:changesignal(pos, node, mesecon:effector_get_rules(node), "on", 1)
|
||||
mesecon:activate(pos, node, nil, 1)
|
||||
else
|
||||
mesecon:changesignal(pos, node, mesecon:effector_get_rules(node), "off", 1)
|
||||
mesecon:deactivate(pos, node, nil, 1)
|
||||
end
|
||||
elseif mesecon:is_conductor_on(node) then
|
||||
minetest.swap_node(pos, {name = mesecon:get_conductor_off(node)})
|
||||
elseif mesecon:is_effector_on (node.name) then
|
||||
mesecon:deactivate(pos, node, nil, 1)
|
||||
end
|
||||